Doc inlet temp during regen.

Jan 23, 2018 · What are the temps showing when you are running the regen? Presuming you are using DDDL? You should see the dpf inlet, the catalyst, the outlet. You want the inlet to show 400, the filter inlet at 450 and above, and the outlet at 450 and above for when the doser will open up and start heating the catalyst up more.

Doc inlet temp during regen. Things To Know About Doc inlet temp during regen.

7. Start the engine and run a Parked Regen. Monitor DOC inlet pressure and engine speed during the regen. Compare your DOC inlet pressure reading to the screen shots below to identify a possible cause of the fault code. a. If the DOC inlet pressure starts out high above 10 kPa (1.45 psi) and decreases during the parked regen, this Here are some of the data I wrote down during the parked regen: DPF DIFFERENTIAL PRESSURE: 0.1hg AFTERTREATMENT FUEL PRESSURE: 14.4psi …120–pin MCM connector and the Turbo Compressor Inlet, DOC Inlet, DOC Outlet, and DPF Outlet temp sensors. Verify repairs. [b] If no voltage is present on pin 1 of the intake air sensor, repair the open between pin 88 of ... during normal service. A stationary regen is required if the fault code is active. No action is required for an inactive ...After DOC reaches operating temperature and stabilizes (see callout 2, graph 8), verify DOCOT and DPFOT signal values are greater than 900°F (482°C). In this graph, DOCOT and DPFOT are less than 900°F (482°C). 2. Verify Diesel Oxidation Catalyst Inlet Temperature (DOCIT) signal value is between 550°F (287°C) to 800°F (427°C).13) Monitor DOC inlet temperature. It MUST be greater than 400°C (750°F). If it is not above 400°C (750°F), block off part of the radiator with cardboard. Be careful that coolant temperatures do not go high enough to cause a Check Engine ight.l 14) Continue to monitor the DOC inlet temperature to make sure it is greater than 400°C (750°F).

Jun 19, 2016 · Fengjun Yan. Control of diesel oxidation catalyst (DOC) outlet temperature is critical for downstream diesel particulate filter regeneration, but is challenging to control due to the non-minimum ... All of the temperatures pressure dosing quantity correct,the whole system removed from the truck and cleaned. Even a DEF tank flushed and refilled. It to the regen starts normally low PPM on the outlet 80% efficiency and then it slowly goes down to 0 and that's it,truck keep regen and it never stops. Any help would be appreciated thanks.

During a stationary (parked) regeneration, these are the typical values for a healthy system. EGR Differential Pressure - Less than 12.7 mm-Hg [0.5 in-Hg] ... Using onsite I can get the engine to start the regen cycle but doc intake temp will not get above 500F.Aftertreatment inlet and aftertreatment Diesel Oxidation Catalyst. (DOC). 2 ... aftertreatment DOC. The oxidation of this additional fuel creates the heat ...

11. After the low temp ATD regeneration has run for 20 minutes, monitor the DOC outlet temperature sensor reading. Is the DOC outlet temperature sensor reading within 25°C (45°F) of the DOC inlet temperature sensor? a. Yes; replace the HC doser block. Refer to section "Removal of the Hydrocarbon Doser Block ". Verify repair. b. Exhaust Gas Temp 572, DOC Inlet Temp 572, DPF Outlet Gas Temp 1013 and still the REGEN process did not want to finish. The tech cleared my ash level to see if that would work and nothing. I got some recommended solutions, drop and burn the DPF / DOC, sensors, etc..ASL: DOC Inlet Temperature ASL: DOC Outlet Temperature ASL: ASL: SCR Outlet Temperature ASL: SCR Inlet NOX Sensor After-treatment Outlet NOX ASL: Nox conversion AAS: Fuel Doser In'ection Status ASL: Exgas mass rate 'd Connections (paused} Device LMCM21J MCM21T MCM21T CPC04T MCM21T MCM21T MCM21T ACM21T ACM21T ACM21T ACM21T ACM21T MCM21T ACM21TResults show that at high DOC inlet temperatures (>190 °C), the DMDF mode combined with DOC achieves the high DPF inlet temperatures and the high NO 2 /PM ratio, which is benefit for passive regeneration. During active regeneration, the initial regeneration temperature, the fuel penalty and the emissions of PM, particulate number (PN), NO 2 ...Regen completed. Didn't set any faults and it brought the soot level down however the NOX readings were never displayed. DPF temps however were not good as the outlet temp remained higher than the inlet temp during the entire regen. Good indication that the DOC is face plugged and I'll recommend the DOC/DPF be sent out for cleaning.

11. After the low temp ATD regeneration has run for 20 minutes, monitor the DOC outlet temperature sensor reading. Is the DOC outlet temperature sensor reading within 25°C …

ASL: DOC Inlet Temperature ASL: DOC Outlet Temperature ASL: ASL: SCR Outlet Temperature ASL: SCR Inlet NOX Sensor After-treatment Outlet NOX ASL: Nox conversion AAS: Fuel Doser In'ection Status ASL: Exgas mass rate 'd Connections (paused} Device LMCM21J MCM21T MCM21T CPC04T MCM21T MCM21T MCM21T ACM21T ACM21T ACM21T ACM21T ACM21T MCM21T ACM21T

Pressure drop and temperature during active regeneration (500°C) DPF inlet temperature: 500°C; Soot load: 4.1 g/dm 3. ΔP C - DOC pressure drop; ΔP F - DPF pressure drop; F - Fuel flow rate T C1 - DOC inlet temperature; T C2 - DOC outlet temperature T F1 - DPF inlet temperature; T F2 - DPF outlet temperatureOct 26, 2018 · Engine Speed 1100 rpm (1275 rpm during first 12 minutes of regen then 1100 rpm for fuelmap ending in ZGS 999) Turbo Speed 45,000 – 60,000 (turbo is used to create pressure in the DD13 and DD15AT only) Fuel Cut Off Valve 100% (once DOC inlet temp reaches 536° F) Engine Torque Around 5% Actual Torque Load 15 – 18% (greater than 20% may ... 9. Start the engine and run a Parked Regen. Monitor DOC inlet pressure and engine speed during the regen. Compare your DOC inlet pressure reading to the screen shots and descriptions below in (a and b) to determine what step to go to next. a. If the DOC inlet pressure starts out high above 10 kPa (1.45 psi) and decreases during the parked regen ...During the DESA NOX sensor test, mine never went above 275ppm inlet and 200 outlet at 1700 rpm. Remember the outlet should always be lower than the inlet due to the DEF being injected into the exhaust prior to the SCR catalyst and passes the outlet sensor on the way out the exhaust pipe. My DPF inlet temp will reach 1250, outlet temp 1200.Still not temp. Have fault traced with G/D. Replaced egr valve. checked diff sensor,tubes,vgt lever,boost leaks,fuel pressure to A/T fuel doser and made sure it wasn't plugged. During regen the exh temps are (inlet 739) (after cat 969-978) (outlet 877-904) It goes back to idle and soot level reads the same and only code active is for soot level.4. If present, check the condition of the insulation material around the exhaust pipe between the turbocharger and the ATD.. 5. Check the ATD mounting bands for tightness. If needed, tighten the mounting bands on horizon-tally and vertically mounted ATDs to 30 lbf·ft (41 N·m); on step-mounted ATDs, tighten the mount-ing bands to 15 lbf·ft (20 N·m).

... DOC-boosted temp of 1100 deg. , we would have ... There WAS distinct mention of a "post" injection, which operated only during active regen,...My unit starts the regen but the DOC inlet temp is only getting to 420 degrees and is not allowing to burn off for the regen. I’m getting codes 4752, (intake manifold pressure sensor) 3719, 3711. Will the intake manifold …Throttle Valve Actual NOT USED DURING A PARKED REGEN Fuel Comp Pressure 85 - 92 psi ... DOC Inlet Temp 700 - 950 ° F DOC Outlet Temp 1050 - 1150° F DPF Inlet Pressure 0.5 psi - 1.0 psi DPF Outlet Pressure 0.01 psi to 0.9 psi Doser Injection Status gradual increase from 5% to 45% • DOC inlet temp must be at 525° F or higher to- During the high speed portion of the test, inlet NOx levels remain above 500 ppm, and outlet NOx levels are approximately 300 ppm as expected. - DTC P220E may be generated when this condition is observed. Replacement of the sensor returns values to the expected range: - If the above condition is present: • Replace the Inlet NOx Sensor2023年8月11日 ... As a whole, the DOC inlet temperature in most working conditions is between 450 °C and 500 °C, which satisfies the set target value. In region 1 ...

My unit starts the regen but the DOC inlet temp is only getting to 420 degrees and is not allowing to burn off for the regen. I’m getting codes 4752, (intake manifold pressure sensor) 3719, 3711. Will the intake manifold …The Aftertreatment System Technician's Guide … NUMBER:08 ATS REF.:Listed in Table :ATSDATE:February 2008 SUBJECT: ADDITIONAL ENGINE WAS ADDEDPUBLICATION: DDC-SVC-MAN-0036 (7SE63)The Aftertreatment System Technician's Guide (DDC-SVC-MAN-0036) wasrevised to include theDD15 REQUIREMENTSA dded row toTable Maintenance …

Apr 7, 2013 · 19 2 Jun 8, 2012 Santa Rosa, CA 0 Can anyone tell me where the temps should be at on an active regen? I keep getting code 1691 DOC below normal operating temp . I cleared code and did regen DOC maxed out at 561F I, inlet 1000+ and outlet 1000+. Is 561F on the DOC inlet right or should it be hotter? Im thinking my doser might be bad. Thanks ASL: DOC Inlet Temperature ASL: DOC Outlet Temperature ASL: ASL: SCR Outlet Temperature ASL: SCR Inlet NOX Sensor After-treatment Outlet NOX ASL: Nox conversion AAS: Fuel Doser In'ection Status ASL: Exgas mass rate 'd Connections (paused} Device LMCM21J MCM21T MCM21T CPC04T MCM21T MCM21T MCM21T ACM21T ACM21T ACM21T ACM21T ACM21T MCM21T ACM21T Start looking at it, doc temps run up to 700 degrees within the first 5 minutes but I never see any pressure kick up from the Hydrocarbon doser. By 10 minute mark all temperatures holding steady around the 400-500 mark. Checked intake/exhaust leaks, intake throttle valve, egr valve, ensure all items are were they should be during the regen process. I have a 2017 Mack/CHU. With an engine light on. The codes that come up are P24D1, P24AF, P249F and P24AO. The first I'm pretty sure is for a … read more. Mike Mcmillan. Shop Foreman/Triage Tech. Associates. 7,331 satisfied customers. I have a 2018 CHU Mack MP8 engine showing me its @ 140% soot.Regen started. DOC inlet go to 750 and both others are around 750 as well. But diagnostic link never shows that regen goes into regeneration state it always shows engine in thermal management.that is why 7th injector never opens. If i manually open 7th injector,it opens and temp rise as well. But it never opens during regen, no other codesThank you for input again, however, i forgot to mention at the very beginning that turbo speed at 58,000 - 60,000 rpm which mean in the boost rate, but DOC and DPF at 350, 400 and 430 degree after 30 minute of regen, but after i detect CAC leak on both side, i replaced CAC and turbo speed back to normal around 42,000-43,000 rpm.The forced regen still shows the DOC temp close to the DPF intake temp and the DPF outlet temp stays around 550-600 but the new thing is that forced regen …Blew out the DOCs during regen I have DPF inlet- 0.363 DPF outlet- 0.072 DOC inlet temp-813 DOC outlet temp-779 Fuel doser-0.0% Fuel cutoff valve- 0.0% Baro-14.43 Intake mani - 14.71 AFS tech, Aug 8, 2019. AFS tech, Aug 8, 2019 #7 + Quote Reply. Aug 8, 2019 #8. spsauerland Road Train Member.

Using DiagnosticLink during the regen, view AS087 Actual Fuel Mass. Is the fuel mass above 100 mg/st? Yes; ... My unit starts the regen but the DOC inlet temp is only getting to 420 degrees and is not allowing to burn off for the regen. I'm getting codes 4752, (intake manifold pressure sensor) 3719, 3711.

Mar 18, 2018 · Tractor was towed in with engine warnings on, and in shutdown mode.Active faults for soot level high, and failed regen. due to temp. Inlet DOC temp only at 425, wont go high enough to start dosing fuel. Intake throttle valve is working. Will continue on diag tomorrow. Any thoughts? Thanks.

Oct 15, 2023 · CM871 High DOC temp during regen. Hi everyone, I have regen issue with my 2009 Volvo with CM871. During Regen instead of DOC temp staying steady and DFP temps going up, this engine shows DPF outlet temp staying steady while DPF intake and DOC temps keep going up (1000+). I have this truck for 3 years and every forced regen i did was successful ... NOTE: The sensor box (item 8) contains the SCR inlet and outlet NOx sensors, DPF outlet pressure sensor, and the DOC inlet pressure sensor. 1. DOC Outlet Temperature Sensor. 2. DOC Inlet Pressure Sensor Port. 3. DOC Inlet Temperature Sensor. 4. Front Heat Shield. 5. DEF Nozzle. 6. Exhaust Outlet. 7. DEF Metering Unit. 8. Sensor Box (see note ...Refer to section "Removal of the EPA07 Temperature Sensors". Verify repair. 5. Monitor the DPF outlet pressure (pin 30) parameter. Is the DPF outlet pressure sensor voltage between 0.44 and 0.56 ... Remove the DOC inlet pressure sensor tube, hose and elbow. Refer to section "Removal of the EPA10 Diesel Oxidation Catalyst Inlet Pressure Sensor ...A) A forced regen will take approximately 40 minutes. It will cycle through 6 stages during this 40 minute period. If the Regen cycle takes longer than this, something else is still wrong. b) During a forced regen cycle, The DOC will get to about 550F, and the doser will activate, first, usually in short intervals, then come on solid.The DPF system is a honeycomb filter, similar to a traditional catalytic converter, that captures and collects particulate soot. The 6.7 Cummins has had a DPF system since halfway through the 2007 model year. 2007.5-2012 models had a completely separate DPF system that sat behind the DOC system. In 2013+ models the DOC and …NOTE: Normal DOC pressure is less than 10 kPa (1.5 psi) for a 1-Box™ emissions package and 13 kPa (1.9 psi) for a Two-Box option. 28. Using DiagnosticLink, monitor DOC inlet pressure while performing a parked regeneration. Refer to section "Performing a Parked Regeneration - GHG17". Does the DOC inlet pressure start out high and stay high? a.During the DESA NOX sensor test, mine never went above 275ppm inlet and 200 outlet at 1700 rpm. Remember the outlet should always be lower than the inlet due to the DEF being injected into the exhaust prior to the SCR catalyst and passes the outlet sensor on the way out the exhaust pipe. My DPF inlet temp will reach 1250, outlet temp 1200.I have volvo d13 2016 it doesn’t raise temperature for Regen though the outlet temp sensor doesn’t go higher when 800 F ... 2018 volvo vnrRequred regen on dash does not Go awaySent filters out for cleaningInatlled back same thisOn regen doc temp stays at 600, dpf inlet 800 and dpf outler 470Put new 7th injector and 7th inj ...Mack MP8 regen issues. 2012 CXU613 with 2012 fault codes so it's not a 2013. Truck arrived at the shop at the beginning of the week. Soot load was level 5. performed a parked regen. DOC inlet temp was bias. DPF outlet temp stayed above inlet temp during regen.Malfunctioning temperature sensors. The temperature sensors, spread through the aftertreatment system, measure the exhaust going into and out of each filter. The first sensor is in the DOC and the last is after the SCR. The sensor’s readings measure how well the system is working, and a faulty sensor can interfere with the regen process.2018年9月18日 ... 3251 21 DOC Inlet / Outlet Pressure Not Plausible Without the ... i think most posts I have read regarding regen said you need to start at ...2018 volvo vnrRequred regen on dash does not Go awaySent filters out for cleaningInatlled back same thisOn regen doc temp stays at 600, dpf inlet 800 and dpf outler 470Put new 7th injector and 7th inj … read more

The regen temps, at least to me, look good for a 2007 emission engine. How does the dpf diff. psi look during the regen? Was the 7th inj. cleaned and if so did you …During a regen the boost psi should be under 10 psi for engines with out a recirculation valve, with the recirculation valve it will be slightly lower. If boost psi is too high remove the sra and verify the turbo sector shaft sweep. It should be smooth and feel a solid stop both ways (there is a tool for verifying full sweep).EGT stands for Exhaust Gas Temperature. The EGT sensor is responsible for reading the temperatures of the aftertreatment system components such as inlet DOC, ...Temperature should NOT MBE 4000 or Exhaust Flap on High DOC Outlet temperature be greater than 100°C (212°F) prior to regen. MBE-900 does NOT close, and there is no HEST Lamp after 25 Monitor smoke control status during regen. Smoke control minutes.) Engine in smoke control mode status should be 0. DOC Inlet Temperature Sensor Monitor DOC ...Instagram:https://instagram. colby basketball playerlamar co craigslistyang wenjunbobby pettiford kansas During vehicle operation, active regeneration is performed when the accumulated soot and ash reach boundary limits. In this operation, the particulate soot is ... molly dickincoporating The Weather Channel and weather.com provide a national and local weather forecast for cities, as well as weather radar, report and hurricane coverage osu vs ku basketball DPF temp should be in the 1000-1100F range. If DPF temp reaches around 1300F, regen will shut down to prevent damage. There are 3 temp sensors but they might be named differently. DPF inlet is also DOC outlet. The 3 temps you listed look very normal.13) Monitor DOC inlet temperature. It MUST be greater than 400°C (750°F). If it is not above 400°C (750°F), block off part of the radiator with cardboard. Be careful that coolant temperatures do not go high enough to cause a Check Engine light. 14) Continue to monitor the DOC inlet temperature to make sure it is greater than 400°C (750°F).Jan 11, 2020 · Force regen after having dpf filters cleaned and temps are as follows After treatment DPF outlet 1024 After treating DPF intake 1041 After treatment diesel oxidation catalyst temp 640 Is this normal 30min I to regen for catalyst to be so low? Any info appreciated Reply Dcmechanical Location Offline Senior Member Reputation: 396 Thanks Given: 952