Ul u373.

UL U336. Area Separation Wall - Wood Stud (Non-Load-Bearing) Fire Rating. 2 hours. System STC. 66. System Thickness. 11.5 in. CAD/Revit & Acoustics.

Ul u373. Things To Know About Ul u373.

UL Design No. W454 (National Gypsum Co.) (2) Layers of 1” thick gypsum board liner panels fit into H-Studs w/ (1) layer of 5/8” thick gypsum board on each side of wall assembly. Standard 2-1/2” long Aluminum Breakaway Clips can be used to secure assembly. 3 Hour UL Assemblies: W454 (1-3/8” flange) 3 hour; W467 (1-3/8” flange) 3 hourEnvironmental Exposures (ANSI/UL 263, ASTM E119) 3. REFERENCED DOCUMENTS ANSI/UL 263, 14th Ed. (ASTM E119), Fire Tests of Building Construction and Materials ANSI/UL 723, 10th Ed. (ASTM E84), Test for Surface Burning Characteristics of Building MaterialsOnly products which bear UL's Mark are considered Certified. BXUV - Fire Resistance Ratings - ANSI/UL 263 Cer tified for United States BXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Cer tified for Canada See General Information for Fire-resistance Ratings - ANSI/UL 263 Certified for United S tates Design Criteria and Allowable Variancesliterature.puertoricosupplier.com

Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C wallboard or DensArmor Plus® Fireguard C panels and 3-1/2” (89 mm) fiberglass insulation in stud space. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information.Acoustic and ire Assemblies HIGHER PERFORMANCE, HIGHER RELIABILITY, LOWER COST SOUNDPROOFING SOLUTIONS. uietRock Type gyp uietRock sound damping dryall and other acoustical products aailable rom Serious Energy Visit www.QuietRock.com or more inormation All uietRock and uietood panels are manuactured under one or more o …

Fire Rated Wall - Home - Henrico County, Virginia

Search Instructions and Resources. Helpful instructions and resources to help you locate UL fire rated assemblies, designs and systems. Fire-resistance rated assemblies. Step-by-step instructions on locating rated walls, floors, beams and columns. Firestop systems.Learn how to design and detail shaft walls made from light wood-frame buildings, such as UL U373, a single-hour single wall with a fire-resistance rating of not …, Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Se rvices' Di-rectory of Listed Products, and the Gypsum Associa-tion's . Fire Resistance Design Manual (GA 600). The American Wood Council (AWC) and its members have tested a number of woodframe fire- -resistance-rated as-semblies (see photos). Descriptions of ...Title: UL Design No. U366 Author: Powers Created Date: 3/26/2007 3:11:58 PMYou have been logged out. You have been logged out due to inactivity

Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-03, cUL U373. Sound Test Reference: RAL TL10-290. Area Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space between liner panels and adjacent wood or metal framing. Sound Tested with 2 ...

Fire Rated Wall - Home - Henrico County, Virginia

the UL fire-resistance ratings that apply to TSN products. Five of The Steel Network’s product lines are approved for use in UL® Classified Head of Wall Assemblies: VertiClip® SLD and DSLD; and VertiTrack® VTD, VTX, and VT. This library contains a list of each Head of Wall assembly that pertains to each of these TSN product lines, followed byAn electronic document associated with a UL Standard for Safety or Outline of Investigation, and issued by UL to propose: A revision of a single or multiple requirement(s). A complete new edition of an existing Standard or Outline.Supporting the world with research and science. UL Research Institutes is a leading independent safety science organization with global reach. We sense and act on risks to public safety with bold hypotheses and objective investigations.Jul 29, 2020 · Standard UL 263 shall be permitted to be used to determine the hourly fire endurance rating of walls and floors with control joints. 1.11 Tests for determining the surface burning characteristics of building materials, based on the rate of flame spread, are found in the Standard for Test for Surface Burning Characteristics of Building Materials ... Note has been added to Detail 1-Common Wall & Detail 6-Common wall on sheet AD-7, referencing UL U373 & UL U336 non-bearing 2-HR area separation items 1,2,3. Depicted below is from manufacturer’s fire rated product installation requirements as approved by ANSI/UL 263. Detail 1-Common Wall & Detail 6-Common Wall follow the design ...

specify use of a UL Classified ceiling damper. UL 555C investigations Ceiling dampers are investigated either as part of the fire-resis-tance-rated floor-ceiling or roof-ceiling assembly or in accordance with requirements in UL 555C, the Standard for Safety for Ceiling Dampers. This standard includes requirements and methods ofIt combines data from many legacy UL solutions, including the Online Certification Directory, Product Spec and several iQ databases into one streamlined experience. A free Product iQ account helps users verify UL certification of products and components, locate UL Solutions guide information and search for alternative certified products.UL-U370 FIREWALL TPICAL FIREWALL TPICAL PARTITION WALL UP - 3 - - 3 SOUND TRANSMISSION CLASS - STC ETTER SOUND ASORPTION ECELLENT VERY OOD OOD MARINAL POOR SOUND TRANSMISSION PERFORMANCE 1. Evaluation Services Report 2016. 2. Comparison based on an R-30 value at one square foot coverage area. …2 Hour UL Listings: U347 (1-3/8” flange) 2 hour; U373 (1-1/2” flange) 2 hour; U388 (1-3/8” flange) 2 hour; V411 (1-3/8” flange) 2 hour; U366 (1-3/8” flange) 2 hour 3 Hour Design Assemblies: UL Design No. W454 (National Gypsum Co.) CGC Sheetrock® Brand Ultracode® Core Panels (UL Type ULTRACODE) • 19.1 mm (3/4") thick panel can achieve a two-hour fire rating with single-layer construction when used with mineral wool insulation in steel framed walls • UL/ULC Classification as to fire resistance, surface burning characteristics and noncombustibilityHuman U373 cells transfected with pCDNA3UL144 were fixed and permeabilized 48 h post-transfection and probed with FITC conjugated anti-T7 (green) and polyclonal anti-TRAF6 followed by anti-rabbit ...ETL listing means that Intertek has determined a product meets ETL Mark safety requirements.. UL listing means that Underwriters Laboratories has determined a product meets UL Mark safety requirements.

Area Separation Wall. Two layers 1” (25.4 mm) ToughRock Shaftliner or DensGlass® Shaftliner inserted in H-Studs 24” (610 mm) o.c. Min. 3/4” (19 mm) air space on both …Title: UL Design No. U338 Author: Powers Created Date: 3/26/2007 3:17:35 PM

, Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Se rvices' Di-rectory of Listed Products, and the Gypsum Associa-tion's . Fire Resistance Design Manual (GA 600). The American Wood Council (AWC) and its members have tested a number of woodframe fire- -resistance-rated as-semblies (see photos). Descriptions of ...UL Classif ied. See complete marking on backof packaging White copy - FRM Specialist Yellow copy - FSP Contractor Manager Pink copy - Builder PM-6 3-122 Rev A US Greenfiber, LLC 5500 77 Center Drive, Suite 100 Charlotte, NC 28217 Toll-Free 800-228-0024 www.greenfiber.com UL-U370 Two-Hour Fire Wall Check List www.literature.puertoricosupplier.comthe UL Fire Resistance Directory under UL Design U373, the ULC Fire Resistance Directory ULC Design No. W312 and the WHI Fire Resistance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2x4 Wood Framing Two 1” (25.4 mm) DensGlass® Shaftliner Panels Batt Insulation 2-Hour Fire Rating Design Reference: UL U373, UL U375, ULC W312, WHI GP/WA 120-03, cUL U373, cUL U375 DensGlass® Shaft liner Area Separat ion Walls For latest information and updates: Technical Service Hotline 1.800.225.6119 or www.gpgypsum.comNov 29, 2022. #1. We have a large apartment complex in design that will need to be divided with multiple fire walls due to the size of the building. The designer doesn’t want to go with freestanding, aka cantilevered CMU fire walls, and has been convinced by the structural engineer that we can use a Gypsum Board Area Separation Wall instead.

Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow­Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide

Jul 1, 2010 · zOnly products which bear UL's Mark are considered as Classified, Listed, or Recognized. Fire Resistance Ratings - ANSI/UL 263 See General Information for Fire Resistance Ratings - ANSI/UL 263 Design No. U497 July 01, 2010 Nonbearing Wall Rating — 2 Hr BXUV.U497 Fire Resistance Ratings - ANSI/UL 263 Page Bottom

BXUV.U347 - Fire-resistance Ratings - ANSI/UL 263 Author: jnye Created Date: 3/13/2017 4:07:02 PM ...Sound Tested with 2”x 4” stud wall with 1/2” (12.7 mm) ToughRock® Fireguard C wallboard or DensArmor Plus® Fireguard C panels and 3-1/2” (89 mm) fiberglass insulation in stud space. Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-03. Consult each listing for specific information.2 Hour UL Listings: U347 (1-3/8” flange) 2 hour; U373 (1-1/2” flange) 2 hour; U388 (1-3/8” flange) 2 hour; V411 (1-3/8” flange) 2 hour; U366 (1-3/8” flange) 2 hour 3 Hour Design Assemblies: UL Design No. W454 (National Gypsum Co.) Get started in Revit by browsing BIM Library on BIMsmith, and downloading our leading materials for your next project. Visit BIM Library. Click here to find and download the CAD and BIM drawings needed for your project. Get started today.Gypsum Board* — Any 5/8 in. thick UL Classified Gypsum Board that is eligible for use in Design Nos. L501, G512 or U305. Nom 5/8 in. thick 4 ft wide. Gypsum board applied horizontally or vertically, unless specified below, and nailed to studs and bearing plates 7 in. OC with 6d cement coated nails, 1-7/8 in. long, 0.0915 in. shank diam …Acoustic and ire Assemblies HIGHER PERFORMANCE, HIGHER RELIABILITY, LOWER COST SOUNDPROOFING SOLUTIONS. uietRock Type gyp uietRock sound damping dryall and other acoustical products aailable rom Serious Energy Visit www.QuietRock.com or more inormation All uietRock and uietood panels are manuactured under one or more o …25 thg 9, 2021 ... Quercetin-loaded platelets as a potential targeted therapy for glioblastoma multiforme cell line U373-MG ... Us · Training and Support · DMCA ...the UL Fire Resistance Directory under UL Design U373, the ULC Fire Resistance Directory ULC Design No. W312 and the WHI Fire Resistance Directory under WHI GP/WA 120-04. Consult the applicable fire resistance directory for additional information. 2x4 Wood Framing Two 1” (25.4 mm) DensGlass® Shaftliner Panels Batt InsulationAgency Related - H-Stud UL U373 (228 Kb, 3pg) Add to Package. Agency Related - H-Stud UL U375 (302 Kb, 4pg) Add to Package. Agency Related - H-Stud UL U388 (199 Kb, 3pg) Add to Package. Test Report - H Stud - MEA 161-05-M (581 Kb, 4pg) Marino\WARE Documents (20) Add to Package.

UL U336. Area Separation Wall - Wood Stud (Non-Load-Bearing) Fire Rating. 2 hours. System STC. 66. System Thickness. 11.5 in. CAD/Revit & Acoustics. literature.puertoricosupplier.comDescription. Curiosity Lab at Peachtree Corners is a city owned and operated living laboratory designed specifically as a proving ground for technology that has "graduated" from a closed laboratory environment. It consists of a 5G-enabled 3-mile autonomous vehicle test track and smart city infrastructure located within an existing 500-acre …BXUV.U375 - BXUV.U375 - Design/System/Construction/Assembly Usage Disclaimer Authorities Having Jurisdiction should be consulted in all cases as to the particular …Instagram:https://instagram. rise up society jiggertouchpaydirect.com commissarybridge repair stardewvladimir duthiers baby • UL Listed E115376 (Ordinary Location) • IECEx and ATEX component certificate – BVS13ATEXE015U and IECEx BVS 13.0025U • 2G Ex eb IIC Gb or 2D Ex tb IIIC Db • TR-CU and EAC certified S-TB-T terminal boxes: S-TB enclosures are available assembled as custom configured and certified terminal boxes. Options include custom entries,2/1/2019 FIRE-RESISTANCE RATINGS - ANSI/UL 263 | UL Product iQ https://iq.ulprospector.com/en/profile?e=14938 5/5 * Indicat es such pr oducts shall bear the UL or cUL Cer tification Mark for jur isdictions employing the UL or cUL Cer tification (such as Canada), respectively. Last Updated on 2018-03-05 rogue trader osrsmarmoset monkey for sale in texas UL 263. August 5, 2021. Fire Tests of Building Construction and Materials. 1 Scope 1.1 These fire tests are applicable to assemblies of masonry units and to composite assemblies of structural materials for buildings, including bearing and other walls and partitions,... UL 263. September 9, 2020.UL U364 Fire-Rated Assembly using ZIP System R-sheathing | UL Assembly. This UL Assembly is designed specifically as a 1-hour rating using ZIP System R-sheathing. dinarvets Breakaway clip facings and height of wall differ between UL Design U373 and WHI GP/WA 120-04. Please consult each listing for specific information. Hourly Rating: 2-hour. STC Rating: 65-69 STC. Fire Test Reference: UL U373, ULC W312, WHI GP/WA 120-04, cUL U373, GA ASW 0810. Sound Test Reference: RAL TL10-291.(15.9 mm) DensGlass® Fireguard® Sheathing is included in a variety of UL and ULC listings and other designs in the GA-600 Fire Resistance Design Manual. Superior Weather Protection DensGlass Sheathing integrates a water-resistant, treated core with a fiberglass mat face and back to provide superb protection from the elements.Environmental Exposures (ANSI/UL 263, ASTM E119) 3. REFERENCED DOCUMENTS ANSI/UL 263, 14th Ed. (ASTM E119), Fire Tests of Building Construction and Materials ANSI/UL 723, 10th Ed. (ASTM E84), Test for Surface Burning Characteristics of Building Materials